Conférence Icare 2017 tracheal stenosis rabbit

Summary

  • A case of tracheal stenosis and its surgical treatment with a coronary stent in a rabbit (oryctolagus cuniculus)
  • Abstract: A four-year-old entire male dwarf rabbit weighting 1.6 kg was presented for an important dyspnea. A computed tomography was performed.
  • The examination of the skull did not show any anomaly. A severe tracheal stenosis in the cervical area was observed. The diameter of the trachea at the level of the stenosis was 0.9 mm and 3.6 mm in the distal neck portion.[1,2]

Auteurs : Drs. Christophe Bulliot, Sophie Romain, Elise Rattez, Antoine Hidalgo, Céline Levrier, Lucas Flenghi. 10-07 -2017
Service NAC – 
Centre Hospitalier Vétérinaire des Cordeliers,
29 avenue du Maréchal Joffre, 77100 Meaux.
E-mail : nac@chvcordeliers.com


 

Conférence Icare 2017 tracheal stenosis rabbit
A case of tracheal stenosis and its surgical treatment with a coronary stent in a rabbit (oryctolagus cuniculus)


A surgical treatment with the use of a coronary stent was performed.
The stent was comprised of a bare of metal stent with a primer coat and a coating that consists of a blend of drug zotarolimus and a polymer system.
The materials required were a guide catheter and an inflation device.

The delivery procedure consisted in introducing the stent in the trachea through an oesophageal tube because an endotracheal intubation was not possible.
The good positioning of the system was controlled with radiography before deployment of the stent.

The rabbit presented a normal breathing immediately after surgery.
Unfortunately, it died two weeks after surgery with sudden dyspnea secondary to rhinitis with rapid evolution. A heat strike has been supposed.
The stent, the trachea and the lungs did not seem to be involved in dyspnea in the light of the radiography and post mortem tracheoscopy.

The use of rabbits as experimental model for human tracheal stenosis and its treatment with coronary stent was documented.[37]

 

References

1. Ajlan,AM, Al-Khatib,T, Al-Sheikah,M, Jastaniah,S, Salih,A, Althubaiti,A, Aljohani,A, Marzouki,H, Alherabi,A, Marglani,O, Rabah,S, Karrouf,G. Helical computed tomography scanning of the larynx and upper trachea in rabbits. Acta Vet Scand. 2015;57-67.
2. Loewen,MS, Walner,DL. Dimensions of rabbit subglottis and trachea. Lab Anim. 2001;35(3):253-256.
3. Chaure J, Serrano C, Fernández-Parra R, Peña E, Lostalé F, De Gregorio MA, Martínez MA, Malvè M. On Studying the Interaction Between Different Stent Models and Rabbit Tracheal Tissue: Numerical, Endoscopic and Histological Comparison. Ann Biomed Eng. 2016;44(2):368-81
4. Kawahara I, Ono S, Maeda K. Biodegradable polydioxanone stent as a new treatment strategy for tracheal stenosis in a rabbit model. J Pediatr Surg. 2016;51(12):1967-1971.
5. Novotny L, Crha M, Rauser P, Hep A, Misik J, Necas A, Vondrys D. Novel biodegradable polydioxanone stents in a rabbit airway model. J Thorac Cardiovasc Surg. 2012;143(2):437-444.
6. Rauber K, Syed-Ali S, Hofmann M, Terpe HJ, Bachmann G, Rau WS. Endotracheal placement of balloon-expanded stents: an experimental study in rabbits. Radiology. 1997;202(1):281-283.
7. Zhu GH, Ng AH, Venkatraman SS, Boey FY, Wee AL, Trasti SL, Yee Lim LH. A novel bioabsorbable drug-eluting tracheal stent. Laryngoscope. 2011;121(10):2234-2239.